208
Classifier the Brain of W-SPECTRA WAVECOM Monitoring System W-SPECTRA, W-SPEED Manual V1.1.0
Code Check
Code check tests whether a candidate mode can successfully synchronize to the input signal for a required
number of times as specified in the corresponding entry in the XML file (<CodecheckCounter>).
Decode
In the CCC workflow P4 and P5 the corresponding decoder will be called. The signal will be decoded with
all detected parameters.
User Interface
The CCC results are mainly displayed in the result window of the W-SPECTRA Operation tab:
Classified signal with its parameter values
Tablecheck results of each signal
Codecheck results of each signal
Jump to the corresponding decoder, if applicable
Status messages of each code check step
All classified signals with their parameters, tablecheck results and codecheck results are displayed
together with the actual receiver frequency (Rx Frequency) in the “Remarks” field
The parameters of the first detected signal will be displayed in the corresponding database field as
well
The entry will be inserted into the database automatically or by the user. The “Date & Time” is the
actual timestamp of the insertion.
Classifier Code Check (CCC) results are displayed in the result window of the Operation tab.