True RMS Industrial Multimeter
MODEL WAVECOM 89
Wavecom Instruments Pty Ltd
257 Grange Road FINDON SA 5023
P: (+61) 08 8243 3500 | F: (+61) 08 8243 3501
[email protected] | www.wavecom.com.au
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - MODEL WAVECOM 89

mA10A10AμHz%AVACVDCMAXMINΩTEMPCAPTEMP True RMS Industrial Multimeter MODEL WAVECOM 89 Wavecom Instruments Pty Ltd 257 Grange Ro

Pagina 2 - Introduction

10 Maintenance WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the back cover or the battery

Pagina 3

11 REPLACING THE FUSES WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the fuse cover. 1. Disc

Pagina 4 - Auto power off

12 Specifications Function Range Resolution Accuracy DC Voltage 600mV 0.1mV (0.09% reading + 2 digits) 6V 0.001V 60V 0.01V 600V 0.1V 1000V 1V (0.15

Pagina 5 - Operating Instructions

13 Function Range Resolution Accuracy Resistance 600 0.1 (0.3% reading + 4 digits) 6k 0.001k 60k 0.01k 600k 0.1k 6M 0.001M 60M 0.01M (0.

Pagina 6

14 Enclosure Double molded, waterproof Shock (Drop Test) 6.5 feet (2 meters) Diode Test Test current of 0.9mA maximum, open circuit voltage 2.8V

Pagina 8

16 Wavecom Instruments Pty Ltd Adelaide 257 Grange Road FINDON SA 5023 Ph: (+61) 08 8243 3500 Fax: (+61) 08 8243 3501 Email: sales@w

Pagina 9

2 Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic), Diode Test, and Co

Pagina 10 - Maintenance

3 SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed

Pagina 11

4 111VAC6mA10AA453210AμHz%MAXMIN87109VDCTEMPΩCAPControls and Jacks 1. 6,000 count LCD display 2. RANGE button 3. Hz and % button 4. Mode button

Pagina 12 - Specifications

5 Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great

Pagina 13

6 DC CURRENT MEASUREMENTS CAUTION: Do not make 20A current measurements for longer than 30 seconds. Exceeding 30 seconds may cause damage to the met

Pagina 14

7 RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any re

Pagina 15

8 TEMPERATURE MEASUREMENTS 1. Set the function switch to the Temp position. 2. Insert the Temperature Probe into the input jacks, making sure to obse

Pagina 16 - Wavecom Instruments Pty Ltd

9 AUTORANGING/MANUAL RANGE SELECTION When the meter is first turned on, it automatically goes into Autoranging. This automatically selects the best r