Wavecom G1900 Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 25
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
Beijing wavecom www.sendsms.cn
7
北京 wavecom 专营店 收集整理 www.sendsms.cn
5.2.2. Electric environment
The following figure sum up electrical constraints in an automotive
environment:
Length of transient
Cause
Energy
capability
Voltage
Amplitude
Possible
frequency of
application
Steady state Failed Voltage Regulator oo
+ 18 V
Infrequent
3 - 5 minutes Jump start with 24 V
battery
oo
+/- 24 V
Infrequent
200ms to 400ms Load dump - i.e.,
disconnection of battery
while at high charging
rates
10 J
125V
Infrequent
< 0.32 s Inductive Load Switching
Transient
<1 J
-300V to +80V
Often
< 0.20 s Alternator Field Decay <1 J
-100V to -40V
Each Turn-Off
90ms Ignition Pulse, Battery
Disconnected
<0.5 J
75V
<500Hz Several
Times in vehicle
Life
1ms Mutual Coupling in
Harness (Note)
<1 J
<200V
Often
15µs Ignition Pulse, Normal <0.001 J
<3V
<500Hz
Continuous
Accessory Noise <1.5V 50 Hz to 10 KHz
Transceiver Feedback 20mV R.F.
Note : These transients may be present on any wire in the vehicle.